refers to a specific Slide-in Strut Tube Storage Kit available at

:

| Symptom | Likely Cause | Solution (Full version only) | |---------|--------------|-------------------------------| | No output, LED off | Reverse polarity or insufficient voltage | Check V+ on pin 1, GND on pin 3. Supply 12V min. | | Erratic readings at high speed | EMI interference | Enable the internal shielding (pin 5). Reduce sampling rate temporarily via register 0x501. | | Modbus timeout | Wrong baud rate | Default full version is 115200 baud. Use auto-baud detect sequence: send three 0xAA bytes. | | Pressure offset >1% FS | Diaphragm damage | Run self-diagnostic: register 0x700 returns error code. 0x03 means overload. | | Cannot write calibration | Register locked | Factory default password for full version is 0x5A5A . Unlock via register 0x600. | pts162 full

If your application demands zero compromises on data fidelity or environmental resilience, the PTS162 Full is the benchmark. refers to a specific Slide-in Strut Tube Storage